济南壁挂炉具有强大的家庭中央供暖功能,能满足多居室的采暖需求,壁挂炉已经成为许多家庭首选的采暖设备。但壁挂炉在使用过程中不可避免的会出现一些故障,具体注意有哪些呢?

1、水压故障,这时要先看一下水压表是不是水压不足,如果不足,补足水就解决了;其次拿出说明书找一下水压开关,水压开关是不是有故障,可以将水压开关的两个电源线对接,看故障是不是可以清楚,如果可以就说明是水压开关有故障,更换配件解决;最后考虑控制器的故障。
This time to look at the pressure gauge is not enough water pressure, if insufficient, make up water will be solved; followed the instructions to find out about the water pressure switch, pressure switch is not a failure, can the two pressure switches power cord docking, see the fault is not clear, if it shows a pressure switch is faulty, replace parts to solve; finally consider the fault of the controller.
2、点火失败,当壁挂炉点不着火时,要看是不是没有天然气了,是不是阀门被关上了;点火和天然气、点火针、燃烧的空气有关系。检查点火针是不是点火的位置,有偏差或者是点火针的电极有漏电,导致电火花点不着火。
Ignition failure, the point when the fireplace is not on fire, look is not no gas, is not the valve is closed; ignition and gas, firing pin, the combustion air has a relationship. Check the ignition is not firing pin position deviation or ignition needle electrode leakage, resulting in a spark point does not fire.
3、风压故障,壁挂炉风压故障主要是风机、风压开关、烟管造成的比较多,可以先看烟管是不是有堵塞,是不是有大风,可以清理烟管和等风停止后按复位键解决;接着检查风压开关,检查风压开关的方法是将风压开关的两个电源线对接,看是不是可以正常,如果可以正常工作,就更换风压开关来尝试;风机故障是可以看出来的,风机只有不转动或者转轴有摩擦造成的;最后考虑控制器的问题。
Pressure failure, boiler pressure failure was mainly fan, air pressure switch, smoke pipe caused more, you can look at the smoke pipe is not a blockage, is not windy, you can clean up the smoke pipe and so on wind stopped pressing the reset key to solve; then check the air pressure switch, pressure switch method is to check the power cord docking of two pressure switches will see is not normal, if normal work, replace the air pressure switch to try; fan failure is look out, the fan does not rotate or only shaft friction caused; finally consider the issue of the controller.
4、过热故障也是常见故障,其原因大多是系统阻力太大和水泵故障造成的。先检查水泵,水泵不转动,可以直接造成高温故障,可以看温度的变换,如果温度不变 或者很小浮动就有可能是水泵故障造成的,打开水泵的一字螺丝,用平口螺丝刀转动中间的转轴直到能轻松转动为止。
Overheating fault is common fault, the reason most of the system too much resistance and pump failure. First check the water pump, the pump does not rotate, can cause temperature fault directly,you can see the temperature of transformation, if the temperature is constant, or there may be a small floating pump failure caused by open slotted screw pumps, rotating in the middle with a flat-blade screwdriver shaft until you can easily turn.
5、壁挂炉采暖开始燃烧水压就急剧升高,就要检查膨胀水箱的故障,看膨胀水箱的气囊是不是漏气了,造成膨胀水箱不承压了。
Boiler heating water pressure began to burn on a sharp rise, it is necessary to check the expansion tank failure, see the expansion tank is not leaking bladder, causing the expansion tank is not confined.
6、温度探头故障,大多是温度探头没接好,或者是壁挂炉使用年数过高,有的温度探头生锈造成的,或者坏死;更换温度探头可以解决。
Temperature probe failure, mostly temperature probe is not connected, or the number of years of excessive use of fireplaces, some rust caused by temperature probe, or necrosis; replace temperature probe can be resolved.